Common problems and solutions for IDC Flat Cable:
1. IDC Flat Cable top compression injury
The reason is that the mold was not properly adjusted. Simply readjust the mold;
2. Wire breakage
The blade is pressed too deeply, causing compression on the insulation skin. The downward stroke of the blade can be adjusted;
3. The wire floats on the IDC Flat Cable
The reason is that the downward pressure of the blade is too shallow, and the downward stroke of the blade can be adjusted;
4. Wire leads to skin breakage and strand breakage
The reason is that the blade is pressed too deeply, which breaks the insulation skin, so the blade pressing stroke is also adjusted;
5. The back of IDC Flat Cable is dirty
It may be that the base is dirty and needs to be cleaned.